Ichi chigadzirwa chakagadzirwa uye chakagadziridzwa mukubvumirana nemitemo inotevera, mirairo uye dhizaini mirau:
◆Council Directive 93/42/EEC ye14 June 1993 maererano nemichina yekurapa(CE yekumaka).
TS EN ISO 13485: 2016 Chishandiso chekurapa - Hunhu manejimendi masisitimu - Zvinodiwa zvekutonga
zvinangwa..
◆ EN ISO 14971: 2012 Midziyo yekurapa - Kushandiswa kwekutonga kwenjodzi kumidziyo yekurapa (ISO 14971: 2007, Corrected version 2007-10-01)
◆ TS EN ISO 15223-1: 2012 Midziyo yekurapa-- Zviratidzo zvekushandisa zvine mavara emudziyo wezvokurapa, manyorerwo uye ruzivo runofanira kupihwa Chikamu 1: Zvizhinji zvinodiwa
◆International Electrotechnical Commission (IEC), zviyero zvinotevera zvinotariswa zvakanyanya.
Standard Reference | Mazita |
EN 60601-2-54:2009 | Zvombo zvemagetsi zvekurapa - Chikamu 2-54: Zvinodiwa zvakanyanya zvekuchengetedza kwekutanga uye kwakakosha kuita kweX-ray michina yeradiography uye radioscopy. |
IEC60526 | Yakakwira-voltage tambo plug uye socket yekubatanidza yekurapa X-ray michina |
IEC 60522:1999 | Kutsunga kwekusefa kwechigarire kweX-ray tube assemblies |
IEC 60613-2010 | Magetsi, kupisa uye kurodha maitiro ekutenderera anode X-ray machubhu ekuongororwa kwechiremba |
IEC60601-1:2006 | Zvigadzirwa zvemagetsi zvekurapa - Chikamu 1: General zvinodiwa zvekuchengetedza kwekutanga uye kwakakosha kuita |
IEC 60601-1-3:2008 | Zvishandiso zvemagetsi zvekurapa - Chikamu 1-3: Zvinodiwa zvakajairika zvekuchengetedza kwekutanga uye kwakakosha kuita - Collateral Standard: Kudzivirirwa kweradiation mune yekuongorora X-ray michina. |
IEC60601-2-28:2010 | Zvishandiso zvemagetsi zvekurapa - Chikamu 2-28: Zvinodiwa zvakanyanya zvekuchengetedza kwekutanga uye kwakakosha kuita kweX-ray tube magungano ekuongororwa kwekurapa. |
IEC 60336-2005 | Zvigadzirwa zvemagetsi zvekurapa-X-ray chubhu magungano ekuongororwa kwekurapa-Unhu hwenzvimbo dzakatariswa |
● Zita racho rinoumbwa sezvinotevera:
MWHX7010 | Tube | A | High voltage socket ine 90 degree direction |
MWTX70-1.0/2.0-125 | B | High voltage socket ine 270 degree direction |
Property | Tsanangudzo | Standard | |
Nominal ekuisa simba(s) eanode | F1 | F 2 | IEC 60613 |
21kW(50/60Hz) | 42.5kW(50/60Hz) | ||
Anode heat storage capacity | 100 kJ ( 140kHU) | IEC 60613 | |
Yakanyanya kutonhora kugona kweanode | 475W | ||
Kukwanisa kuchengetedza kupisa | 900kJ | ||
Max. kupfuurira kupisa kupera pasina Air-denderedzwa | 180W | ||
Anode zvinhuAnode top coating material | Rhenium-Tungsten-TZM(RTM) Rhenium-Tungsten-(RT) | ||
Kona yechinangwa (Ref: referensi axis) | 16 ° | IEC 60788 | |
X-ray chubhu musangano inherent filtration | 1.5 mm Al / 75kV | IEC 60601-1-3 | |
Focal spot nominal value(s) | F1 (kutarisisa kudiki) | F2 (yakanyanya kutarisisa) | IEC 60336 |
1.0 | 2.0 | ||
X-ray chubhu nominal voltageRadiographic Fluoroscopic | 125kV 100kV | IEC 60613 | |
Data pane cathode kudziyisa Max. current Max voltage | ≈ / AC, <20 kHz | ||
F1 | F 2 | ||
5.1A ≈5.8~7.8V | 5.1 A ≈7.7~10.4 V | ||
Leakage radiation pa150 kV / 3mA mu1m chinhambwe | ≤1.0mGy/h | IEC60601-1-3 | |
Maximum radiation field | 573 × 573mm paSID 1m | ||
X-ray chubhu musangano uremu | Approx. 18 kg |
Miganhu | Operation Limits | Kutakura uye Kuchengeta Miganhu |
Ambient tembiricha | Kubva ku10℃kusvika ku40℃ | Kubva-20℃to 70℃ |
Hunyoro hwehukama | ≤75% | ≤93% |
Barometric pressure | Kubva 70kPa kusvika 106kPa | Kubva 70kPa kusvika 106kPa |
1-chikamu stator
Test point | C-M | C-A |
Kupokana nemhepo | ≈18.0…22.0Ω | ≈45.0…55.0Ω |
Max.inobvumirwa kushanda voltage(run-up) | 230V±10% | |
Kurudzira kushanda kwemagetsi (run-up) | 160V±10% | |
Braking voltage | 70VDC | |
Run-on voltage in exposure | 80Vrms | |
Run-on voltage mu fluoroscopy | 20V-40Vrms | |
Nguva yekumhanya (zvichienderana neyekutanga system) | 1.2s |
Yambiro yekubatanidza neX-ray Jenareta
1.Kuparara Kwedzimba
Usambofa wakaisa pamusoro peyakayerwa simba kuX-ray chubhu kusangana
Kana simba rekuisa richipfuura zvakatemwa nechubhu, zvinogona kukonzera kuti anode iwedzere kupisa, girazi rechubhu riparare, uye pakupedzisira rinogona kukonzera matambudziko makuru nekuda kwekuwedzeredza kunokonzerwa nekunyungudika kwemafuta mukati megungano redzimba. Mumamiriro ezvinhu akaoma apo imba inoputika nekuda kwekuremerwa, kuchengetedzwa kwekushisa kwekushisa kunogona kusakwanisa kuchengetedza X-ray tube, kunyange kana iri kushanda.
*Imba yekuisa chisimbiso zvikamu zvinoputika.
*Kukuvara kwevanhu kunosanganisira kutsva nekuda kwekubuda kwemafuta anopisa.
*Tsaona yemoto nekuda kwekutsva anode chinangwa.
Iyo X-ray jenareta inofanirwa kunge iine basa rekudzivirira iro rinokwanisa kupinza simba kuti rive mukati mechubhu yakatarwa.
2.Electric Shock
Kuti udzivise njodzi yekuvhunduka kwemagetsi, iyi midziyo inofanirwa kungobatanidzwa kune inopihwa ine inodzivirira pasi.
3.No kuchinjwa kwechigadzirwa ichi kunobvumirwa !!
Yambiro yekubatanidza neX-ray Jenareta
1.Kupfuura Rating
Simba rakawandisa mupfuti rimwe chete rinogona kukonzera X-ray chubhu kusangana kukundikana.Zvakakosha kuti unyatso ongorora technical data sheet uye uteedzere mirairo yakatarwa kuti usakuvare.
2.Permanent Filtration
Mitemo yepamutemo inotsanangura huwandu hwesefa inodiwa uye diki chinhambwe pakati peX-ray yekutarisisa nzvimbo uye muviri wemunhu.
They inofanira kutevedzwa nemutemo.
3.Safety Thermal Switch
X-ray chubhu musangano ine chengetedzo yekudziya yekuchinja kurambidza imwe simba rekuisa kana chubhu imba yasvika kune tembiricha(80℃)yekuchinja-kuvhura.
Iyo switch haina kukurudzirwa kubatanidza stator coil munhevedzano wedunhu.
Kunyangwe iyo switch ikashanda, usambodzima system system. Iyo yekutonhodza unit inofanirwa kuitwa activated kana ikashandiswa nesystem.
4.Kusatarisika Kusingatarisirwi
X-ray tube assemblies inogona kusashanda kana kukundikana zvisingatarisirwi, zvichigadzira njodzi yezvinetso zvakakomba. Izvo zvakakosha kuve nehurongwa hwenjodzi panzvimbo yekudzivirira nekugadzirisa chero matambudziko angangomuka kubva munjodzi iyi.
5.New Application
Kana ukaronga kushandisa chigadzirwa ichi muchirongwa chitsva chisina kutaurwa mugwaro rino, kana kana ukaronga kushandisa imwe mhando yeX-ray jenareta, ndapota taura nesu kuti tisimbise kuenderana uye kuwanikwa.
1 .X-ray Radiationkudzivirira
Ichi chigadzirwa chinozadzisa zvinodiwa zveIEC 60601-1-3.
Iyi X-ray chubhu musangano inoburitsa X-ray mwaranzi mukushanda.Izvo chete zvinoenderana vanokwanisa uye vakadzidziswa vashandi saka vanobvumirwa kushandisa X-ray chubhu musangano.
Yakakodzera physiologic mhedzisiro inogona kukonzera kukuvadza kune murwere, sisitimu yekugadzira inofanirwa kutora kuchengetedzwa kwakaringana kudzivirira ionization radiation.
2.Dielectric 0il
X-ray chubhu musangano ine dielectric 0il inowanikwa kune yakakwira voltage kugadzikana. Sezvo ine chepfu kuhutano hwevanhu,kana yakaratidzwa kune nzvimbo isingabvumirwi,inofanira kuraswa sezvinotevera kumutemo wenzvimbo.
3 .Operation Atmosphere
X-ray tube assembly haibvumidzwe kushandiswa mumhepo ine gasi rinopfuta kana rinoparadza ·
4.Gadzirisa Tube Yazvino
Zvichienderana nemamiriro ekushanda,maitiro e filament anogona kuchinjwa.
Shanduko iyi inogona kuendesa kune yakawedzera chiyero kuratidzwa kuX-ray chubhu musangano.
Kudzivirira X-ray chubhu musangano kubva kukuvara,gadzirisa chubhu ikozvino nguva dzose.
Kunze kweiyo X-ray chubhu ine arcing Dambudziko munelkushandiswa kwenguva refu,kugadziriswa kwechubhu ikozvino kunodiwa.
5.X-ray Tube Housing Temperature
Usabate paX-ray chubhu pekugara pachangopera kushanda nekuda kwekupisa kwakanyanya.
Gara X-ray chubhu kuti itonhodzwe.
6.Operating limits
Isati yashandiswa,ndapota simbisa mamiriro ezvakatipoteredza ari mukati meIimits yekushandisa.
7.Chero Mafunction
P1sese kubata kuSAILRAY nekukurumidza,kana chero kusashanda kweX-ray chubhu musangano kunoonekwa.
8.Kurasa
Iyo X-ray chubhu musangano pamwe nechubhu ine zvinhu zvakaita seoiri nesimbi dzinorema izvo zvinotenderedza zvakatipoteredza uye zvakakodzera kuraswa zvinoenderana nemutemo wepamutemo wemitemo yenyika zvinofanirwa kuve nechokwadi. Kurasa semarara epamba kana emumaindasitiri hazvibvumirwi. Mugadziri anawo. iyo inodiwa ruzivo rwehunyanzvi uye inotora X-ray chubhu musangano kudzoka kuti inoraswa.
Ndokumbira ubate basa revatengi nekuda kweizvi.
Kana (A) Diki Focal Spot
Kana (A) Yakakura Focal Spot
Mamiriro ezvinhu:Tube Voltage Three-Phase
Stator Power Frequency 50Hz/60Hz
IEC60613
Housing Thermal Characteristics
SRMWHX7010A
SRMWHX7010B
Sefa Gungano Uye Muchinjikwa Chikamu chePort
Rotor Connector Wiring
Minimum Order Quantity: 1pc
Mutengo: Kukurukurirana
Packaging Details: 100pcs per carton kana customized maererano nehuwandu
Nguva Yekutumira: 1 ~ 2 mavhiki maererano nehuwandu
Kubhadhara Mitemo: 100% T / T pamberi kana WESTERN UNION
Kugovera Mano: 1000pcs / mwedzi