China X-ray Tube Assembly yakaenzana neE7252X RAD14 Manufacturer uye Supplier | Sailray
X-ray Tube Assembly yakaenzana neE7252X RAD14

X-ray Tube Assembly yakaenzana neE7252X RAD14

X-ray Tube Assembly yakaenzana neE7252X RAD14

Tsanangudzo Pfupi:

◆ X-ray chubhu kusangana kwese kwese kwemaitiro ekuongorora bvunzo neyakajairwa kana digital radiographic uye fluoroscopic workstations.
◆ High-speed inotenderera anode x-ray tube kuisa
◆ Iyo yekuisa zvinhu: 12 ° Rhenium-Tungsten molybdenum chinangwa (RTM)
◆ Nzvimbo dzekutarisa: Diki 0.6, Yakakura: 1.2
◆Maximum tube voltage: 150kV
◆Inogara neIEC60526 mhando yepamusoro-voltage cable receptacles
◆ High voltage jenareta inofanira kuenderana neIEC60601-2-7
◆IEC Classification (IEC 60601-1:2005): Kirasi I ME EQUIPMENT

Product Detail

Kubhadhara & Kutumira Mitemo:

Product Tags

Mitemo, zviyero nemirairo

Ichi chigadzirwa chakagadzirwa uye chakagadziridzwa mukubvumirana nemitemo inotevera, mirairo uye dhizaini mirau:
◆Council Directive 93/42/EEC ye14 June 1993 maererano nemichina yekurapa(CE yekumaka.
TS EN ISO 13485: 2016 Chishandiso chekurapa - Hunhu manejimendi masisitimu - Zvinodiwa zvekutonga
zvinangwa..
◆ EN ISO 14971: 2012 Midziyo yekurapa - Kushandiswa kwekutonga kwenjodzi kumidziyo yekurapa (ISO 14971: 2007, Corrected version 2007-10-01)
◆ TS EN ISO 15223-1: 2012 Midziyo yekurapa-- Zviratidzo zvekushandisa zvine mavara emudziyo wezvokurapa, manyorerwo uye ruzivo runofanira kupihwa Chikamu 1: Zvizhinji zvinodiwa
International Electrotechnical Commission (IEC), zviyero zvinotevera zvinotariswa zvakanyanya.

Standard Reference

Standard Reference

Mazita

EN 60601-2-54:2009 Zvombo zvemagetsi zvekurapa - Chikamu 2-54: Zvinodiwa zvakanyanya zvekuchengetedza kwekutanga uye kwakakosha kuita kweX-ray michina yeradiography uye radioscopy.
IEC60526 Yakakwira-voltage tambo plug uye socket yekubatanidza yekurapa X-ray michina
IEC 60522:1999 Kutsunga kwekusefa kwechigarire kweX-ray tube assemblies
IEC 60613-2010 Magetsi, kupisa uye kurodha maitiro ekutenderera anode X-ray machubhu ekuongororwa kwechiremba
IEC60601-1:2006 Zvigadzirwa zvemagetsi zvekurapa - Chikamu 1: General zvinodiwa zvekuchengetedza kwekutanga uye kwakakosha kuita
IEC 60601-1-3:2008 Zvishandiso zvemagetsi zvekurapa - Chikamu 1-3: Zvinodiwa zvakajairika zvekuchengetedza kwekutanga uye kwakakosha kuita - Collateral Standard: Kudzivirirwa kweradiation mune yekuongorora X-ray michina.
IEC60601-2-28:2010 Zvishandiso zvemagetsi zvekurapa - Chikamu 2-28: Zvinodiwa zvakanyanya zvekuchengetedza kwekutanga uye kwakakosha kuita kweX-ray tube magungano ekuongororwa kwekurapa.
IEC 60336-2005 Zvigadzirwa zvemagetsi zvekurapa-X-ray chubhu magungano ekuongororwa kwekurapa-Unhu hwenzvimbo dzakatariswa

Tsanangudzo

● Zita racho rinoumbwa sezvinotevera:

MWHX7360

Tube

A

High voltage socket ine 90 degree direction

MWTX73-0.6/1.2-150H

B

High voltage socket ine 270 degree direction

Technical Data

Property

Tsanangudzo

Standard

Nominal ekuisa simba(s) eanode

F1

F 2

IEC 60613

20kW (50/60Hz)
30kW(150/180Hz
50kW (50/60Hz)
74kW(150/180Hz)
 

Anode heat storage capacity

212 kJ (300kHU)

IEC 60613

Yakanyanya kutonhora kugona kweanode

750W

 
Kukwanisa kuchengetedza kupisa

900kJ

 
Max. kupfuurira kupisa kupera pasina Air-denderedzwa

180W

 
Anode zvinhuAnode top coating material

Rhenium-Tungsten-TZM(RTM)

Rhenium-Tungsten-(RT)

 
Kona yechinangwa (Ref: referensi axis)

12 °

IEC 60788

X-ray chubhu musangano inherent filtration

1.5 mm Al / 75kV

IEC 60601-1-3

Focal spot nominal value(s)

F1 (kutarisisa kudiki)

F2 (yakanyanya kutarisisa)

IEC 60336

0.6

1.2

 
X-ray chubhu nominal voltageRadiographicFluoroscopic

150kV

125kV

IEC 60613

Data pane cathode kudziyisa Max. current

Max voltage

≈ / AC, <20 kHz

 

F1

F 2

 

5.4A

≈9V

5.4 A

≈17V

 
Leakage radiation pa150 kV / 3mA mu1m chinhambwe

1.0mGy/h

IEC60601-1-3

Maximum radiation field

430 × 430mm paSID 1m
 
X-ray chubhu musangano uremu

Approx. 18 kg

 

Mamiriro ekushanda, kuchengetedza uye kutakura

Miganhu

Operation Limits

Kutakura uye Kuchengeta Miganhu

Ambient tembiricha

Kubva ku10kusvika ku40

Kubva-20to 70

Hunyoro hwehukama

≤75%

≤93%

Barometric pressure

Kubva 70kPa kusvika 106kPa

Kubva 70kPa kusvika 106kPa

 

Stator key values

1-chikamu stator

Test point

C-M

C-A

Kupokana nemhepo

≈18.0…22.0Ω

≈45.0…55.0Ω

Max.inobvumirwa kushanda voltage(run-up)

230V±10%

Kurudzira kushanda kwemagetsi (run-up)

160V±10%

Braking voltage

70VDC

Run-on voltage in exposure

80Vrms

Run-on voltage mu fluoroscopy

20V-40Vrms

Nguva yekumhanya (zvichienderana neyekutanga system)

1.2s

Yambiro

Yambiro yekubatanidza neX-ray Jenareta

1.Kuparara Kwedzimba
Usambofa wakaisa pamusoro peyakayerwa simba kuX-ray chubhu kusangana
Kana iyo simba rekuisa richipfuura kutaurwa kwechubhu, rinokonzeresa tembiricha yeanode, isa chubhu yegirazi shatter uye pakupedzisira matambudziko akakomba anotevera nekuda kwekugadzira-kudzvanywa nemafuta vaporization mukati megungano redzimba.
Mumamiriro ezvinhu akaoma kudaro zvichiita kuti imba iparare nekuremerwa, iyo yekuchengetedza inopisa kupisa haigone kuchengetedza X-ray chubhu kunyangwe ikashanda.
Imba yekuisa chisimbiso zvikamu zvinoputika.
Kukuvara kwevanhu kunosanganisira kutsva nekuda kwekubuda kwemafuta anopisa.
Tsaona yemoto nekuda kwekutsva anode chinangwa.
Iyo X-ray jenareta inofanirwa kunge iine basa rekudzivirira iro rinokwanisa kupinza simba kuti rive mukati mechubhu yakatarwa.

2.Electric Shock
Kuti udzivise njodzi yekuvhunduka kwemagetsi, iyi midziyo inofanirwa kungobatanidzwa kune inopihwa ine inodzivirira pasi.

 3.No kuchinjwa kwechigadzirwa ichi kunobvumirwa !!

Yambiro

Yambiro yekubatanidza neX-ray Jenareta

1.Kupfuura Rating
X-ray tube assembly inogona kuputswa nekushandisa imwe chete pamusoro peyakatemerwa pfuti.
Ndokumbira uverenge mapepa emazuva ehunyanzvi uye tevera mirairo.

2.Permanent Filtration
Tiye zvachose kusefa uye chinhambwe chiri pakati peX-ray focal spot uye muviri wemunhu zvinodzorwa zviri pamutemo.
They inofanira kutevedzwa nemutemo.

3.Safety Thermal Switch
X-ray chubhu musangano ine chengetedzo yekudziya yekuchinja kurambidza imwe simba rekuisa kana chubhu imba yasvika kune tembiricha(80yekuchinja-kuvhura.
Iyo switch haina kukurudzirwa kubatanidza stator coil munhevedzano wedunhu.
Kunyangwe iyo switch ikashanda, usambodzima system system. Iyo yekutonhodza unit inofanirwa kuitwa activated kana ikashandiswa nesystem.

4.Kusatarisika Kusingatarisirwi
X-ray tube assembly inogona kuva nengozi yekusashanda zvisingatarisirwi nekuda kwekuguma kwehupenyu kana kukundikana.Kana matambudziko akakomba anokonzerwa nengozi iri pamusoro apa anotarisirwa, iwe unokumbirwa kuti uve nechirongwa chekudzivisa dambudziko rakadaro.

5.New Application
Kana iwe ukashandisa chigadzirwa nechishandiso chitsva chisingataurwe mune iyi yakatarwa kana nemhando dzakasiyana dzeX-ray jenareta, ndapota taura nesu kuti tisimbise kuwanikwa kwayo.

Kuchenjerera muKushanda

1 .X-ray Radiationkudzivirira

Ichi chigadzirwa chinozadzisa zvinodiwa zveIEC 60601-1-3.

Iyi X-ray chubhu musangano inoburitsa X-ray mwaranzi mukushanda.Izvo chete zvinoenderana vanokwanisa uye vakadzidziswa vashandi saka vanobvumirwa kushandisa X-ray chubhu musangano.

Yakakodzera physiologic mhedzisiro inogona kukonzera kukuvadza kune murwere, sisitimu yekugadzira inofanirwa kutora kuchengetedzwa kwakaringana kudzivirira ionization radiation.

2.Dielectric 0il

X-ray chubhu musangano ine dielectric 0il inowanikwa kune yakakwira voltage kugadzikana. Sezvo ine chepfu kuhutano hwevanhu,kana yakaratidzwa kune nzvimbo isingabvumirwi,inofanira kuraswa sezvinotevera kumutemo wenzvimbo.

3 .Operation Atmosphere

X-ray tube assembly haibvumidzwe kushandiswa mumhepo ine gasi rinopfuta kana rinoparadza ·

4.Gadzirisa Tube Yazvino

Zvichienderana nemamiriro ekushanda,maitiro e filament anogona kuchinjwa.

Shanduko iyi inogona kuendesa kune yakawedzera chiyero kuratidzwa kuX-ray chubhu musangano.

Kudzivirira X-ray chubhu musangano kubva kukuvara,gadzirisa chubhu ikozvino nguva dzose.

Kunze kweiyo X-ray chubhu ine arcing Dambudziko munelkushandiswa kwenguva refu,kugadziriswa kwechubhu ikozvino kunodiwa.

5.X-ray Tube Housing Temperature

Usabate paX-ray chubhu pekugara pachangopera kushanda nekuda kwekupisa kwakanyanya.

Gara X-ray chubhu kuti itonhodzwe.

6.Operating limits

Isati yashandiswa,ndapota simbisa mamiriro ezvakatipoteredza ari mukati meIimits yekushandisa.

7.Chero Mafunction

P1sese kubata kuSAILRAY nekukurumidza,kana chero kusashanda kweX-ray chubhu musangano kunoonekwa.

8.Kurasa

Iyo X-ray chubhu musangano pamwe nechubhu ine zvinhu zvakaita seoiri nesimbi dzinorema izvo zvinotenderedza zvakatipoteredza uye zvakakodzera kuraswa zvinoenderana nemutemo wepamutemo wemitemo yenyika zvinofanirwa kuve nechokwadi. Kurasa semarara epamba kana emumaindasitiri hazvibvumirwi. Mugadziri anawo. iyo inodiwa ruzivo rwehunyanzvi uye inotora X-ray chubhu musangano kudzoka kuti inoraswa.

Ndokumbira ubate basa revatengi nekuda kweizvi.

Emission curves ye cathode

MWHX7360 小焦点发射图
MWHX7360 大焦点发射图

Kana (A) Diki Focal Spot

Kana (A) Yakakura Focal Spot

Kupisa uye kutonhora curve yeanode
MWHX7360 kudziyisa uye kutonhora curve

Kupisa uye kutonhora curve yeX-ray chubhu musangano

Housing Thermal Characteristics

MWHX7360 HOUSING HEATING UYE KUTONHORA

X-ray chubhu musangano dimensional mifananidzo

SRMWHX7360A

MWHX7360外形图

Sefa Gungano Uye Muchinjikwa Chikamu chePort

图片 27

Rotor Connector Wiring

图片 28

  • Zvakapfuura:
  • Zvinotevera:

  • Minimum Order Quantity: 1pc

    Mutengo: Kukurukurirana

    Packaging Details: 100pcs per carton kana customized maererano nehuwandu

    Nguva Yekutumira: 1 ~ 2 mavhiki maererano nehuwandu

    Kubhadhara Mitemo: 100% T / T pamberi kana WESTERN UNION

    Kugovera Mano: 1000pcs / mwedzi

    Nyora meseji yako pano ugotitumira